Maintenance Tips
Home - Maintenance Tips
  • Lubricant addition

    Loosen the screw on the oil plug, insert the correct oil refueling oil in a place slightly above the center line, and then install the plug.
    There is no need to supply fuel to the reducer (motor).

  • To Start

    Before you begin, you should check and record for the following purposes:

    1.Oil level
    2.Oil cooling or oil supply system for pipe seals
    3.Effect of shaft seal
    4.The rotating part is not in contact with other parts.

  • Operation

    The starting of the speed reducer (motor) should, if possible, operate for no more than a few hours under no-load conditions. If there is no abnormality, the load may gradually increase.
    The reducer must be monitored during operation.
    Oil temperature (Design temperature of reducer for continuous operation: Continuous operation for mineral oil use, use synthetic oil at 90 ℃, high temperature, maximum temperature can reach 100 ℃ during short time operation);
    Running noise change;
    The housing and shaft seal may leak.
    Accurate oil level height;

  • Maintenance

    If the repair is unsuccessful, it should be done by the customer service department. After the warranty period and any unspecified reasons have occurred, please contact the customer service department.

  • Inspection & Maintenance Frequency
    Measures Frequency
    Oil temperature check Daily
    Abnormal sound silencer check Monthly
    Confirmation of reducer leakage Monthly
    Check oil level height Before starting the gear reducer
    Checking the water ratio of the oil 400 hours after start of operation
    1st oil change 400 hours after startup, at least once a year
    Followed oil change Every 18 months or 5000 hours
    Oil filter cleaning Every 3 months
    Screw ventilation valve cleaning Every 3 months
    Clean fan and fan covers and decelerating boxes Depending on your requirements or cleaning with oil change at the same time
    Check cooling coil scale About every 2 years or at the same time with oil change
    Oil water cooler check At the same time with oil change
    Bolt fastening degree check After the first oil change, once every two oil changes
    Comeprehensice reducer check About every 2 years or at the same time with oil change